Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters

Database
Language
Document Type
Year range
1.
ACS Appl Mater Interfaces ; 15(12): 15195-15202, 2023 Mar 29.
Article in English | MEDLINE | ID: covidwho-2264408

ABSTRACT

Rapid diagnosis of coronavirus disease 2019 (COVID-19) is key for the long-term control of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) amid renewed threats of mutated SARS-CoV-2 around the world. Here, we report on an electrical label-free detection of SARS-CoV-2 in nasopharyngeal swab samples directly collected from outpatients or in saliva-relevant conditions by using a remote floating-gate field-effect transistor (RFGFET) with a 2-dimensional reduced graphene oxide (rGO) sensing membrane. RFGFET sensors demonstrate rapid detection (<5 min), a 90.6% accuracy from 8 nasal swab samples measured by 4 different devices for each sample, and a coefficient of variation (CV) < 6%. Also, RFGFET sensors display a limit of detection (LOD) of pseudo-SARS-CoV-2 that is 10 000-fold lower than enzyme-linked immunosorbent assays, with a comparable LOD to that of reverse transcription-polymerase chain reaction (RT-PCR) for patient samples. To achieve this, comprehensive systematic studies were performed regarding interactions between SARS-CoV-2 and spike proteins, neutralizing antibodies, and angiotensin-converting enzyme 2, as either a biomarker (detection target) or a sensing probe (receptor) functionalized on the rGO sensing membrane. Taken together, this work may have an immense effect on positioning FET bioelectronics for rapid SARS-CoV-2 diagnostics.


Subject(s)
COVID-19 , Graphite , Humans , SARS-CoV-2 , COVID-19/diagnosis , COVID-19 Testing , Saliva
2.
Nano Lett ; 23(1): 98-106, 2023 01 11.
Article in English | MEDLINE | ID: covidwho-2185486

ABSTRACT

Directly identifying the presence of the virus in infected hosts with an appropriate speed and sensitivity permits early epidemic management even during the presymptomatic incubation period of infection. Here, we synthesize a bioinspired plasmo-virus (BPV) particle for rapid and sensitive point-of-care (POC) detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) via a self-assembled plasmonic nanoprobe array on spike proteins. The BPV enables strong near-infrared (NIR) extinction peaks caused by plasmonic nanogaps. We quantify SARS-CoV-2 in viral transport medium (VTM) at low titers within 10 min with a limit of detection (LOD) of 1.4 × 101 pfu/mL, which is 103 times more sensitive than the current gold-standard method. The high-sensitivity and high-speed POC detection may be widely used for the timely, individualized diagnosis of infectious agents in low-resource settings.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , COVID-19/diagnosis , Point-of-Care Systems , COVID-19 Testing , Limit of Detection
3.
ACS Appl Mater Interfaces ; 14(21): 24187-24196, 2022 Jun 01.
Article in English | MEDLINE | ID: covidwho-1860277

ABSTRACT

Despite intensive research of nanomaterials-based field-effect transistors (FETs) as a rapid diagnostic tool, it remains to be seen for FET sensors to be used for clinical applications due to a lack of stability, reliability, reproducibility, and scalability for mass production. Herein, we propose a remote floating-gate (RFG) FET configuration to eliminate device-to-device variations of two-dimensional reduced graphene oxide (rGO) sensing surfaces and most of the instability at the solution interface. Also, critical mechanistic factors behind the electrochemical instability of rGO such as severe drift and hysteresis were identified through extensive studies on rGO-solution interfaces varied by rGO thickness, coverage, and reduction temperature. rGO surfaces in our RFGFET structure displayed a Nernstian response of 54 mV/pH (from pH 2 to 11) with a 90% yield (9 samples out of total 10), coefficient of variation (CV) < 3%, and a low drift rate of 2%, all of which were calculated from the absolute measurement values. As proof-of-concept, we demonstrated highly reliable, reproducible, and label-free detection of spike proteins of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in a saliva-relevant media with concentrations ranging from 500 fg/mL to 5 µg/mL, with an R2 value of 0.984 and CV < 3%, and a guaranteed limit of detection at a few pg/mL. Taken together, this new platform may have an immense effect on positioning FET bioelectronics in a clinical setting for detecting SARS-CoV-2.


Subject(s)
Biosensing Techniques , COVID-19 , Graphite , COVID-19/diagnosis , Graphite/chemistry , Humans , Reproducibility of Results , SARS-CoV-2 , Spike Glycoprotein, Coronavirus , Transistors, Electronic
SELECTION OF CITATIONS
SEARCH DETAIL